PTFE-Coated Seldinger Guidewires

Coloplast offers a variety of fixed and movable core PTFE-coated Seldinger guidewires intended to facilitate the placement of devices during interventional procedures.

Quick Look

PTFE-Coated Seldinger Guidewires

  • Facilitates the placement of devices during interventional procedures
  • PTFE coating offers a smooth wire surface to facilitate advancement
  • Precise control and positioning
  • Flexible tip for atraumatic advancement
  • Radiopaque for fluoroscopic visualization

Ordering Information

Fixed Core PTFE-Coated Seldinger Guidewires
Item Shaft Diameter Tip Length (cm) Sales UOM EA / Sales UOM
AE0032 Standard 0.032″ Straight 150 Retail Box 5 EA
AE0035 Standard 0.035″ Straight 150 Retail Box 5 EA
AE0038 Standard 0.038″ Straight 150 Retail Box 5 EA
AE0E32 Standard 0.032″ Straight 90 Retail Box 5 EA
AE0E38 Standard 0.038″ Straight 90 Retail Box 5 EA
AE0C35 Stiff 0.035″ Straight 150 Retail Box 5 EA
AE1138 Stiff 0.038″ J Tip 80 Retail Box 5 EA

 

Movable Core PTFE-Coated Seldinger Guidewires
Item Shaft Diameter Tip Length (cm) Sales UOM EA / Sales UOM
AE0A32 Standard 0.032″ Straight 150 Retail Box 5 EA
AE0A35 Standard 0.035″ Straight 150 Retail Box 5 EA
AE0A38 Standard 0.038″ Straight 150 Retail Box 5 EA
AE0D35 Stiff 0.035″ Straight 150 Retail Box 5 EA

PTFE-Coated Seldinger Guidewire Brief Statement

Indications
All endourologic procedures or percutaneous urologic procedures requiring a guidewire. Stiff guidewires are particularly indicated for the insertion of a percutaneous nephrostomy.

Contraindications

  • These guidewires are not intended for use other than for endourologic procedures.
  • Do not use, when, in the judgement of the physician, such a procedure would be contrary to the best interest of the patient.
  • Any contraindication of the endourological procedure (untreated urinary tract infection, uncorrected haemostasis disorder).

Warnings and Precautions

  • The Seldinger guidewires are P.T.F.E coated.
  • Do not kink the guidewire. If the guidewire becomes kinked it cannot be used. Do not try to straighten the guidewire if it has become kinked.
  • Do not resterilize this product.
  • The risks and benefits of using Seldinger guidewire should be considered in patients.
  • Do not use if the patient has an allergy to device components.

Potential Complications

  • Do not use this guidewire with any electrosurgical equipment such as an electric scalpel to avoid the risk of iatrogenic burns.
  • Perforation of the ureter is a classic risk connected with the use of a guidewire.
  • It is advisable to proceed slowly and with caution to avoid it, inserting the guidewire flexible tip first

The information provided is not comprehensive with regard to product risks. For a comprehensive listing of indications, contraindications, warnings and precautions refer to the product’s Instructions for Use. Alternatively, you may contact a Coloplast representative at 1-800-258-3476 and/or visit the company Website at www.coloplast.com.

For Rx Only

Caution: Federal (USA) law restricts this device to sale by or on the order of a physician.
Minneapolis, MN
06/10/2020